No.Condition Text
1.This permission expires on 30th. May 2002 and unless on or before this date application has been made for an extention to the period of permission and such application is approved by the Local Planning Authority the structures shall be removed from the site. The reason for the condition is:- To enable the Local Planning Authority to retain control over the structures which are of a temporary nature and in the interests of the visual amenities of the locality.
2.Any facilities for the storage of oils,fuels or chemicals shall be sited on impervious bases and surrounded by impervious bund walls.The volume of the bunded compound should be at least the equivalent to the capacity of the tank plus 10%.All filling points,vents,gauges and sight glasses must be located within the bund.The drainage system of the bund shall be sealed with no discharge to any watercourse,land or underground strata.Associated pipework should be located above ground and protected from accidental damage.All filling points and tank overflow pipe outlets should be detailed to discharge downwards into the bund. The reason for the condition is :- To prevent pollution of the water environment.
3.NOTES - Please read the following notes carefully:- The applicant is advised that the Environment Agency has indicated that only clean surface water from roofs and roads should discharge to any soakaway,watercourse or surface water sewer and that it must be ensured that there is no discharge of effluent from the site to any watercourse or surface water drain or sewer.