No.Condition Text
1.The development must be begun not later than five years beginning with the date of this permission. The reason for the condition is :- Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990.
2.Prior to any work commencing on the site details shall be submitted of works to increase the height of the mounding on the 7.5 metre wide area of buffer strip on the southern boundary of the site. The details shall include a scheme of planting and landscaping which shall be submitted for the approval of the Local Planning Authority and the planting of trees and shrubs shall be carried out in accordance with the scheme as approved in the 1998/99 planting season. Any trees and shrubs which die, are removed, become seriously damamged or dieseased within 5 years shall be replaced within one year by the applicant ot their sucessors in title unless the Local Planning Authority gives written consent to any variation. The reason for the condition is:- To ensure the provision of the adjoining section of the Gapton Hall Buffer strip in the interests of the visual amenities of the locality and the residential amenities of the occupiers of nearby dwellings.
3.No work shall commence until the exact type and colour of the facing bricks and roof tiles have been submitted to and approved by the Local Planning Authority. The reason for the condition is :- In the interests of the visual amenities of the area as precise details of these materials have not been submitted.
4.No storage shall take place on the car parking and manouevring area indicated on the approved plan. The reason for the condtion is:- In order to ensure the retention and availability of the approved car parking areas.
5.The premises hereby approved shall not be used for any purpose other than those included in Class B1 or B8 of the Town and Country Planning (Use Classes) Order 1987. The reason for the condition is:- To ensure compliance with the Borough Council's policy of restricting development on that part of the Gapton Hall Industrial Estate that is within 50 metres of the buffer strip which separates the industrial estate from residential development, to light industrial, offices, warehouse or ancillary car parking uses.
6.Notwithstanding the details indicated on the submitted plan the boundary fence indicated in red on the attached plan shall not exceed 1.06 metres in height and the fence shall thereafter be retained at this height. The reason for the condition is:- In the interests of highway safety and to safeguard intervisibility between users of adjoining sites.
7.Before the development is commenced a scheme of planting and landscaping shall be submitted for the approval of the Local Planning Authority and the planting of trees and shrubs shall be carried out in accordance with the scheme as approved within six months of the approval. Any trees and shrubs so planted which die within 5 years shall be replaced within one year by the applicants or their sucessors in title. The reason for the condition is:- To enhance the visual amenities of the locality
8.Prior to any work commencing on the development hereby permitted details shall be submitted of the fencing to be used along the frontage of the site and works in accordance with such details as may be approved shall be completed prior to the office being brought into use, unless otherwise agreed in writing with the Local Planning Authority. The reason for the condition is:- In the interests of the visual amenities of the locality.
9.NOTES - Please read the following notes carefully:-
10.The Council's Access Officer has requested that the following items be incorporated in the proposed development in the interests of people with disabilities :- (i) level or ramped approaches to all doorways (1:20 maximum slope preferred), (ii) level standing at doorways, (iii) flush thresholds, and (iv) wide (900mm preferred, 838mm minimum) easy to open doors. The applicants attention is drawn to the attached sketch showing improved toilet provision of toilets suitable for use by wheelchair users.
11.Comments from Anglian Water:- The sewers shown on the applicants plan are not recorded by us as public sewers. Any proposals to connect to these pipes will require the approval of the Building Control Officer