| No. | Condition Text |
|---|
| 1. | The development must be begun not later than five years beginning with the
date of this permission.
The reason for the condition is :-
Required to be imposed pursuant to Section 91 of the Town and Country
Planning Act 1990. |
| 2. | Prior to the use hereby permitted commencing details of the layout of the
yard at the rear of the premises, detailing the area to be provided for
car parking, open storage and working area and such details are approved
by the Local Planning Authourity and all works in accordance with such
details as may be approved shall be completed within three months of the
approval of the details.
The reason for the condition is:-
To ensure the provision of adequate parking provision to serve the
development in accordance with the Council's adopted standards and for the
avoidance of doubt. |
| 3. | Prior to the use hereby permitted commencing detailed drawings of the
surfacing of the yard area together details of the drainage to be provided
within the yard and such details shall be approved by the Local Planning
Authority in consultation with the National Rivers Authority. The works
in accordance with such details as may be approved shall be completed
within six months of the date of the approval.
The reason for the condition is:-
For the avoidance of doubt and to prevent pollution of the water
environment. |
| 4. | Any facilities for the staorage of oils, fuels or chemicals shall be sited
on impervious bases and surrounded by impervious bund walls. The volume
of the bunded compound should be at least equivalent to the capacity of the
tank plus 10%. If there is multiple tankage, the compound should be at
least the capacity of the largest tank, or the combined capacity of
interconnected tanks, plus 10%. All filling points, vents, gauges and sight
glasses must be located within the bund. The drainage system of the bund
shall be sealed with no discharge to any watercourse, land or underground
strata. Associated pipework should be located above ground and protected
from accidental damage. All filling points and tank overflow pipe outlets
should be detailed to discharge downwards into the bund.
The reason for the condition is:-
To prevent pollution of the water environment. |
| 5. | No goods or other materials shall be stored outside the frontage of the
building fronting onto Boudary Road unless otherwise specified in
writing by the Local Planning Authority.
The reason for the condition is:-
In the interests of the amenities of the occupiers of the adjacent
premises and the visual amenities of the locality. |
| 6. | NOTES - Please read the following notes carefully:-
The applicant is advised that the details submitted with the letter dated
13th December 1995 are inadequate and do not meet the requirement of the
above conditions. The details should be shown on scale drawings with
parking spaces indicated in accordance with the Council's adopted standards
a copy of which is attached for information.
The Access Officer recommends the following facilities are included if
theses facilities are not already provided:-
i) Ramped approaches
ii) Level standings at doors
iii) Flush tresholds
iv) Wide (900mm) easy to open doors
v) A 2 metre x 1.5 metre disabled person toilet which all can use
The National Rivers Authority makes the following recommendations:-
All drums and small containers used for oil and other chemicals shall be
stored in bunded areas which do not drain to any watercourse, surface
water sewer or soakaway.
Vehicle loading or unloading bays and storage areas invoving chemicals,
refuse or other polluting matter, shall not be connected to a surface
water sewer.
Facilities should be provided to ensure that waste oil is stored and
disposed of in a manner that will not lead to pollution.
Only clean uncontaminated surface water, should be discharged to any
soakaway, watercourse or surface water sewer.
The Lower Bure Internal Drainage Board were consulted and made the
following comment: The applicant should advise the Board on their proposals
for surface water drainage. |