| No. | Condition Text |
|---|
| 1. | The development must be begun not later than three years beginning with the date of this permission.
The reason for the condition is :-
The time limit condition is imposed in order to comply with the requirements of Section 91 of the Town and Country Planning Act 1990 as amended by Section 51 of the Planning and Compulsory Purchase Act 2004. |
| 2. | The development hereby permitted shall be carried out in accordance with the amended plans numbered 626/1A, 626/2A, 626/3 & 626/4 and submitted on 30th November 2010.
The reason for the condition is :-
For the avoidance of doubt. |
| 3. | No development shall take place outside of the following hours:
Monday to Friday 07:30-18:00
Saturday 08:00-13:00
Other hours including Sundays and Bank Holidays - no work producing audible noise at the nearest noise sensitive property shall take place.
The reason for the condition is :-
To maintian the amenities of any adjacent residents. |
| 4. | REASON FOR APPROVAL OF THE APPLICATION :-
The proposal meets the provisions of the Great Yarmouth Borough Wide Local Plan and, in particular, policies HOU7, HOU15, BNV5 & BNV6. |
| 5. | NOTES - Please read the following notes From Environmental Health and Norfolk Constabulary carefully:-
ENVIRONMENTAL HEALTH:
The cafe and restaurant that is situated on the ground floor level should have some form of fire detection system that is interlinked to the residential system on the 1st and 2nd floors.
There should be a 60-minute imperforate fire separaration between the commercial and residential use.
NORFOLK CONSTABULARY:
Multi occupancy buildings are considerably more vulnerable to forced entry through the entry doors to each flat. Vulnerable areas are the door frames and areas around locks and hinges. The door sets should comply with PAS 23/24 as set out in the 'Secured by Design' specification for flat entrance doorsets served off a shared corridor or stairway.
Communal entrance doors should be of a similar standard to resist forced entry. Fitted with automatic closing device, and an automatic deadlocking lock with an internal thumb turn, knob or handle.
For convenience and safety the entrance door should be incorporated with an access control system with electronic latch release and entry phone.
External lighting over external doors should be vandal resistant and be controlled by phopo sesnitive switch.
Windows accessible from any flat roof at first floor level should be to BS 7950 with laminated and toughened double glazing. |